Robotics in Cervical Spine Surgery: Feasibility and Safety of Posterior Screw Placement

颈椎手术中的机器人技术:后路螺钉置入的可行性和安全性

阅读:1

Abstract

OBJECTIVE: Robot-assisted (RA) techniques have been widely investigated in thoracolumbar spine surgery. However, the application of RA methods on cervical spine surgery is rare due to the complex morphology of cervical vertebrae and catastrophic complications. Thus, the feasibility and safety of RA cervical screw placement remain controversial. This study aims to evaluate the feasibility and safety of RA screw placement on cervical spine surgery. METHODS: A comprehensive search on PubMed, Cochrane Library, Embase Database, Web of Science, Chinese National Knowledge Databases, and Wanfang Database was performed to select potential eligible studies. Randomized controlled trials (RCTs), comparative cohort studies, and case series reporting the accuracy of cervical screw placement were included. The Cochrane risk of bias criteria and Newcastle-Ottawa Scale criteria were utilized to rate the risk of bias of the included literatures. The primary outcome was the rate of cervical screw placement accuracy with robotic guidance; subgroup analyses based on the screw type and insertion segments were also performed. RESULTS: One RCT, 3 comparative cohort studies, and 3 case series consisting of 160 patients and 719 cervical screws were included in this meta-analysis. The combined outcomes indicated that the rates of optimal and clinically acceptable cervical screw placement accuracy under robotic guidance were 88.0% (95% confidence interval [CI], 84.1%-91.4%; p = 0.073; I2 = 47.941%) and 98.4% (95% CI, 96.8%-99.5%; p = 0.167; I2 = 35.954%). The subgroup analyses showed that the rate of optimal pedicle screw placement accuracy was 88.2% (95% CI, 83.1%-92.6%; p = 0.057; I2 = 53.305%); the rates of optimal screw placement accuracy on C1, C2, and subaxial segments were 96.2% (95% CI, 80.5%-100.0%; p = 0.167; I2 = 44.134X%), 89.7% (95% CI, 80.6%-96.6%; p = 0.370; I2 = 0.000X%), and 82.6% (95% CI, 70.9%-91.9%; p = 0.057; I2 = 65.127X%;), respectively. CONCLUSION: RA techniques were associated with high rates of optimal and clinically acceptable screw positions. RA cervical screw placement is accurate, safe, and feasible in cervical spine surgery with promising clinical potential.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。