A 2-year multicenter, observational, prospective, cohort study on extracorporeal CO(2) removal in a large metropolis area

一项为期两年的多中心、观察性、前瞻性队列研究,旨在探讨大型都市区体外二氧化碳清除术的疗效。

阅读:1

Abstract

BACKGROUND: Extracorporeal carbon dioxide removal (ECCO(2)R) is a promising technique for the management of acute respiratory failure, but with a limited level of evidence to support its use outside clinical trials and/or data collection initiatives. We report a collaborative initiative in a large metropolis. METHODS: To assess on a structural basis the rate of utilization as well as efficacy and safety parameters of 2 ECCO(2)R devices in 10 intensive care units (ICU) during a 2-year period. RESULTS: Seventy patients were recruited in 10 voluntary and specifically trained centers. The median utilization rate was 0.19 patient/month/center (min 0.04; max 1.20). ECCO(2)R was started under invasive mechanical ventilation (IMV) in 59 patients and non-invasive ventilation in 11 patients. The Hemolung Respiratory Assist System (Alung) was used in 53 patients and the iLA Activve iLA kit (Xenios Novalung) in 17 patients. Main indications were ultraprotective ventilation for ARDS patients (n = 24), shortening the duration of IMV in COPD patients (n = 21), preventing intubation in COPD patients (n = 9), and controlling hypercapnia and dynamic hyperinflation in mechanically ventilated patients with severe acute asthma (n = 6). A reduction in median V (T) was observed in ARDS patients from 5.9 to 4.1 ml/kg (p <0.001). A reduction in PaCO(2) values was observed in AE-COPD patients from 67.5 to 51 mmHg (p< 0.001). Median duration of ECCO(2)R was 5 days (IQR 3-8). Reasons for ECCO(2)R discontinuation were improvement (n = 33), ECCO(2)R-related complications (n = 18), limitation of life-sustaining therapies or measures decision (n = 10), and death (n = 9). Main adverse events were hemolysis (n = 21), bleeding (n = 17), and lung membrane clotting (n = 11), with different profiles between the devices. Thirty-five deaths occurred during the ICU stay, 3 of which being ECCO(2)R-related. CONCLUSIONS: Based on a registry, we report a low rate of ECCO(2)R device utilization, mainly in severe COPD and ARDS patients. Physiological efficacy was confirmed in these two populations. We confirmed safety concerns such as hemolysis, bleeding, and thrombosis, with different profiles between the devices. Such results could help to design future studies aiming to enhance safety, to demonstrate a still-lacking strong clinical benefit of ECCO(2)R, and to guide the choice between different devices. TRIAL REGISTRATION: ClinicalTrials.gov: Identifier: NCT02965079 retrospectively registered https://clinicaltrials.gov/ct2/show/NCT02965079.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。