Calibrated cardiac output monitoring versus standard care for fluid management in the shocked ICU patient: a pilot randomised controlled trial

校准心输出量监测与标准治疗在休克ICU患者液体管理中的比较:一项试点随机对照试验

阅读:1

Abstract

BACKGROUND: Despite the evidence for calibrated cardiac monitored devices to determine fluid responsiveness, there is minimal evidence that the use of cardiac output monitor devices leads to an overall change in IV fluid use. We sought to investigate the feasibility of performing a randomised controlled study using calibrated cardiac output monitoring devices in shocked ICU patients and whether the use of these devices led to a difference in total volume of IV fluid administered. METHODS: We performed a single-centre non-blinded randomised controlled study which included patients who met the clinical criteria for shock on admission to ICU. Patients were divided into two groups (cardiac output monitors or standard) by block randomisation. Patients allocated to the cardiac output monitor all received EV1000 with Volume View sets. Daily intravenous fluid administration and cumulative fluid balance was recorded for 3 days. The primary outcome assessed was the difference in daily intravenous fluid administration and cumulative fluid balance at 72 h between the two groups. We also assessed how often the clinicians used the cardiac monitor to guide fluid therapy and the different reasoning for initiating further intravenous fluids. RESULTS: Eighty patients were randomised and 37 received calibrated cardiac output monitors. We found no adverse outcomes in the use of calibrated cardiac output monitoring devices and that was feasible to perform a randomised controlled trial. There was no significant difference between the standard care group vs the cardiac monitoring group for cumulative fluid balance (2503 ± 3764 ml vs 2458 ± 3560 ml, p = 0.96). There was no significant difference between the groups for daily intravenous fluid administration on days 1, 2 or 3. In the cardiac monitored group, only 43% of the time was the EV1000 output incorporated into the decision to give further intravenous fluids. CONCLUSION: It is feasible to perform a randomised controlled trial using calibrated cardiac output monitoring devices. In addition, there was no trend to suggest that the use of a cardiac monitors leads to lower IV fluid use in the shocked patient. Further trials will require study designs to optimise the use of a cardiac output monitor to determine the utility of these devices in the shocked patient. TRIAL REGISTRATION: ANZCTR, ACTRN12618001373268. Registered 15 August 2018-retrospectively registered.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。