Regional impact of time-to-equilibrium on indirect Patlak whole-body parametric imaging: a multi-tissue class analysis at the entire body level

平衡时间对间接Patlak全身参数成像的区域性影响:基于全身水平的多组织类别分析

阅读:1

Abstract

PURPOSE: Patlak parametric imaging is widely employed for kinetic modeling due to its simplicity and robustness. The time-to-equilibrium (t*), which must be defined to estimate kinetic parameters, is currently set empirically and uniformly across the entire body. In this study, we evaluate the regional impact of varying t* values on kinetic parameter estimates using a multi-tissue segmentation approach at the whole-body level. METHODS: Data from 53 patients who underwent one-hour dynamic 18 F-FDG PET/CT scans were retrospectively analyzed. Parametric maps of the net influx rate (K(i)) and blood distribution volume (dv) were calculated for four t* values (10, 20, 30, and 45 min) using in-house software (PET KinetiX). Voxel-wise K(i) and dv values were extracted from 10 predefined tissue structures through automated segmentation. Using t* = 30 min as the widely accepted reference, relative mean errors and relative absolute mean errors of K(i) and dv estimated at t*shifts = 10, 20 and 45 min were calculated for each tissue. Pearson correlation coefficients between K(i) or dv reference values and those estimated at t* shifts = 10, 20, and 45 min were also computed. RESULTS: Compared to the reference t*30, K(i) estimates ranged from - 21.4% (liver) to 7.3% (SAT) at t*10, and from - 13.8% (lungs) to 2.4% (brain) at t*20. Median absolute bias was 12.8% at t*10 (6.5% brain to > 25% liver) and 8.6% at t*20 (3.2% brain to > 15% lungs and liver). At t*45, K(i) was consistently overestimated, with a median bias of 19.4% (2.7% brain to > 33% lungs and liver) and median absolute bias of 19.8% (5.5% brain to > 33% lungs and liver). For dv, biases ranged from - 25.2% (brain) to 8.6% (spleen) at t*10; - 13.7% (brain) to 5.7% (lungs) at t*20; - 15.5% (liver) to 8.8% (brain) at t*45. Median absolute biases were 14.0% at t*10 (9.8% heart to 25.2% brain), 9.4% at t*20 (7.7% heart to 14.1% brain), and 15% at t*45 (12.4% skeletal muscle to 18.5% brain). Regardless of t*, K(i) values exhibited strong linear correlations (r > 0.7) across all organs, whereas dv correlations showed greater variability, falling below 0.7 in 80% of organs at t*45. CONCLUSION: Kinetic parameter sensitivity to time-to-equilibrium (t*) varies across organs in Patlak whole-body parametric imaging, underscoring the necessity of adopting flexible or adaptive t* values at the whole-body level.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。