Comparison of SZ-HRX and LEHR collimators for reduced-duration 123I-ioflupane brain SPECT/CT: a phantom study

比较 SZ-HRX 和 LEHR 准直器在缩短 123I-碘氟烷脑 SPECT/CT 显像中的应用:一项体模研究

阅读:1

Abstract

BACKGROUND: (123)I-ioflupane Single Photon Emission Computed Tomography with Computed Tomography (SPECT-CT) imaging is widely used to assess dopaminergic denervation in parkinsonian syndromes, such as Parkinson's disease and atypical variants. Standard imaging generally uses low-energy high-resolution (LEHR) parallel-hole collimators, which require long acquisition times and minimal source-to-detector distance to optimize spatial resolution. Recently, the Smart-Zoom High-Resolution and eXtended magnification volume (SZ-HRX) solution was designed specifically for neurological applications. It incorporates multifocal collimators and a dedicated reconstruction algorithm, promising a reduction in acquisition duration, and an improvement in patient comfort by allowing detectors to be positioned further away from the head. The aim of this study is to investigate the performance of SZ-HRX system compared to LEHR collimators. METHODS: A striatal phantom with 5 compartments (putamens, caudates, and background) was filled with different concentrations of (123)I-ioflupane to simulate various clinical situations. Tomographic acquisitions were performed on each LEHR and SZ-HRX system. The summation of dynamically acquired projections allowed testing different acquisition durations with the SZ-HRX collimator. Sensitivity and Spatial resolution were assessed and compared. The data were reconstructed according to EANM recommendations. Contrast-to-noise ratio (CNR), striatum-to-background ratio (SBR), coefficient of variation (CV), and normalized asymmetry index (NAI) were calculated for both systems and compared to the LEHR acquisition. To estimate the shortest SZ-HRX acquisition duration, a linear regression of all quantitative results were calculated between the two systems. RESULTS: SZ-HRX collimation had superior performance characteristics than LEHR, with relative changes in CNR, CV, and SBR of + 99%, -28% and + 42% respectively, without any decrease in spatial resolution or change in asymmetry index. SZ-HRX system seems to be at least as good as LEHR system, up to 40% of scan time reduction. CONCLUSION: SZ-HRX collimation showed superior performance characteristics to LEHR collimation in the study of (123)I-ioflupane filled striatal phantom, enabling shorter acquisitions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。