A novel method for harmonization of PET image spatial resolution without phantoms

一种无需体模即可协调PET图像空间分辨率的新方法

阅读:1

Abstract

BACKGROUND: Estimation of the spatial resolution in real images is extremely important in several fields, including crystallography, optics, microscopy, and tomography. In human PET imaging, estimating spatial resolution typically involves the acquisition of images from a physical phantom, typically a Hoffman phantom, which poses a logistical burden, especially in large multi-center studies. Indeed, phantom images may not always be readily available, and this method requires constant monitoring of scanner updates or replacements, scanning protocol changes, and image reconstruction guidelines to establish a equivalence with scans acquired from human subjects. METHODS: We propose a new computational approach that allows estimation of spatial resolution directly from human subject PET images. The proposed technique is based on the generalization of the logarithmic intensity plots in the 2D Fourier domain to the 3D case. The spatial resolution of the image is obtained through the estimated coefficients of a multiple linear regression problem having the logarithm of the squared norm of the Fourier transform as dependent variable and the squared 3D frequencies as multiple predictors. RESULTS: The proposed approach was applied to a cohort of subjects consisting of [18F]florbetapir amyloid PET images and matching phantoms from a Phase II clinical trial, and a second cohort including β-amyloid, FDG, and tau PET images from the Alzheimer's Disease Neuroimaging Initiative (ADNI) study. The resulting in-plane and axial resolution estimators varied between 3.5 mm and 8.5 mm for both PET and matching phantom images. They also yielded less than one voxel size across-subjects variability in groups of images sharing the same PET scanner model and reconstruction parameters. For human PET images, we also proved that the spatial resolution estimators showed: (1) a very high reproducibility, as measured by intraclass correlation coefficients (ICC > 0.985), (2) a strong cross-tracer linear correlations, and (3) a high within-subject longitudinal consistency, as measured by the maximum difference value between pairs of visits from the same subject. CONCLUSIONS: Our novel approach does not only eliminate the need for surrogate phantom data, but also provides a general framework that can be applied to a wide range of tracers and other imaging modalities, such as SPECT. CLINICAL TRIAL DATA: Cognito Therapeutics' OVERTURE clinical trial (NCT03556280, 2021-08-24), https://clinicaltrials.gov/study/NCT03556280 .

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。