Optimization of Q.Clear reconstruction for dynamic (18)F PET imaging

针对动态 (18)F PET 成像的 Q.Clear 重建优化

阅读:1

Abstract

BACKGROUND: Q.Clear, a Bayesian penalized likelihood reconstruction algorithm, has shown high potential in improving quantitation accuracy in PET systems. The Q.Clear algorithm controls noise during the iterative reconstruction through a β penalization factor. This study aimed to determine the optimal β-factor for accurate quantitation of dynamic PET scans. METHODS: A Flangeless Esser PET Phantom with eight hollow spheres (4-25 mm) was scanned on a GE Discovery MI PET/CT system. Data were reconstructed into five sets of variable acquisition times using Q.Clear with 18 different β-factors ranging from 100 to 3500. The recovery coefficient (RC), coefficient of variation (CV(RC)) and root-mean-square error (RMSE(RC)) were evaluated for the phantom data. Two male patients with recurrent glioblastoma were scanned on the same scanner using (18)F-PSMA-1007. Using an irreversible two-tissue compartment model, the area under curve (AUC) and the net influx rate K(i) were calculated to assess the impact of different β-factors on the pharmacokinetic analysis of clinical PET brain data. RESULTS: In general, RC and CV(RC) decreased with increasing β-factor in the phantom data. For small spheres (< 10 mm), and in particular for short acquisition times, low β-factors resulted in high variability and an overestimation of measured activity. Increasing the β-factor improves the variability, however at a cost of underestimating the measured activity. For the clinical data, AUC decreased and K(i) increased with increased β-factor; a change in β-factor from 300 to 1000 resulted in a 25.5% increase in the K(i). CONCLUSION: In a complex dynamic dataset with variable acquisition times, the optimal β-factor provides a balance between accuracy and precision. Based on our results, we suggest a β-factor of 300-500 for quantitation of small structures with dynamic PET imaging, while large structures may benefit from higher β-factors. TRIAL REGISTRATION: Clinicaltrials.gov, NCT03951142. Registered 5 October 2019, https://clinicaltrials.gov/ct2/show/NCT03951142 . EudraCT no 2018-003229-27. Registered 26 February 2019, https://www.clinicaltrialsregister.eu/ctr-search/trial/2018-003229-27/NO .

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。