Estimation of kidney doses from [(177)Lu]Lu-DOTA-TATE PRRT using single time point post-treatment SPECT/CT

利用单次治疗后SPECT/CT估算[(177)Lu]Lu-DOTA-TATE PRRT治疗的肾脏剂量

阅读:1

Abstract

BACKGROUND: Dosimetry after [(177)Lu]Lu-DOTA-TATE therapy can be demanding for both patients and the clinical service due to the need for imaging at several time points. In this work we compare three methods of single time point (STP) kidney dosimetry after [(177)Lu]Lu-DOTA-TATE therapy with a multiple time point (MTP) dosimetry method. METHOD: Method 1 (MTP): Kidney doses were calculated from 31 patients including 107 therapy cycles. Post-therapy SPECT images were acquired on day 0, 4 and 7 along with a CT scan on day 4. A mono-exponential fit was used to calculate kidney doses using cycle specific data. Method 2 (Consistent effective half-life): The effective half-life [Formula: see text] calculated in cycle 1 was assumed consistent for subsequent cycles of therapy and the activity scaled using a single day 3-5 SPECT/CT. Methods 3 and 4 (Hänscheid and Madsen approximations): The Hänscheid approximation and Madsen approximation were both evaluated using a single SPECT/CT acquired on day 0, 4 and 7. All STP methods were compared to the MTP method for accuracy. RESULTS: Using the MTP method, mean right and left kidney doses were calculated to be 2.9 ± 1.1 Gy and 2.8 ± 0.9 Gy respectively and the population [Formula: see text] was 56 ± 13 h. For the consistent [Formula: see text], Hänscheid and Madsen methods, the percentage of results within ± 20% of MTP method were 96% (n = 70), 95% (n = 80) and 94% (n = 80) respectively. CONCLUSION: All three single time point methods had > 94% of results within ± 20% of the MTP method, however the consistent [Formula: see text] method resulted in the highest alignment with the MTP method and is the only method which allows for calculation of the patient-specific [Formula: see text]. If only a single scan can be performed, day 4 is optimal for kidney dosimetry where the Hänscheid or Madsen approximation can be implemented with good accuracy.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。