Automated quantification of baseline imaging PET metrics on FDG PET/CT images of pediatric Hodgkin lymphoma patients

对儿童霍奇金淋巴瘤患者的FDG PET/CT图像进行基线成像PET指标的自动定量分析

阅读:1

Abstract

PURPOSE: For pediatric lymphoma, quantitative FDG PET/CT imaging features such as metabolic tumor volume (MTV) are important for prognosis and risk stratification strategies. However, feature extraction is difficult and time-consuming in cases of high disease burden. The purpose of this study was to fully automate the measurement of PET imaging features in PET/CT images of pediatric lymphoma. METHODS: (18)F-FDG PET/CT baseline images of 100 pediatric Hodgkin lymphoma patients were retrospectively analyzed. Two nuclear medicine physicians identified and segmented FDG avid disease using PET thresholding methods. Both PET and CT images were used as inputs to a three-dimensional patch-based, multi-resolution pathway convolutional neural network architecture, DeepMedic. The model was trained to replicate physician segmentations using an ensemble of three networks trained with 5-fold cross-validation. The maximum SUV (SUV(max)), MTV, total lesion glycolysis (TLG), surface-area-to-volume ratio (SA/MTV), and a measure of disease spread (Dmax(patient)) were extracted from the model output. Pearson's correlation coefficient and relative percent differences were calculated between automated and physician-extracted features. RESULTS: Median Dice similarity coefficient of patient contours between automated and physician contours was 0.86 (IQR 0.78-0.91). Automated SUV(max) values matched exactly the physician determined values in 81/100 cases, with Pearson's correlation coefficient (R) of 0.95. Automated MTV was strongly correlated with physician MTV (R = 0.88), though it was slightly underestimated with a median (IQR) relative difference of - 4.3% (- 10.0-5.7%). Agreement of TLG was excellent (R = 0.94), with median (IQR) relative difference of - 0.4% (- 5.2-7.0%). Median relative percent differences were 6.8% (R = 0.91; IQR 1.6-4.3%) for SA/MTV, and 4.5% (R = 0.51; IQR - 7.5-40.9%) for Dmax(patient), which was the most difficult feature to quantify automatically. CONCLUSIONS: An automated method using an ensemble of multi-resolution pathway 3D CNNs was able to quantify PET imaging features of lymphoma on baseline FDG PET/CT images with excellent agreement to reference physician PET segmentation. Automated methods with faster throughput for PET quantitation, such as MTV and TLG, show promise in more accessible clinical and research applications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。