A novel planar image-based method for bone marrow dosimetry in (177)Lu-DOTATATE treatment correlates with haematological toxicity

一种用于(177)Lu-DOTATATE治疗中骨髓剂量测定的新型平面图像方法与血液学毒性相关

阅读:1

Abstract

BACKGROUND: (177)Lu-DOTATATE is a valuable treatment option for patients with advanced neuroendocrine tumours overexpressing somatostatin receptors. Though well tolerated in general, bone marrow toxicity can, besides renal exposure, become dose limiting and affect the ability to sustain future therapies. The aim of this study was to develop a novel planar image-based method for bone marrow dosimetry and evaluate its correlation with haematological toxicity during (177)Lu-DOTATATE treatment. In this study, 46 patients with advanced neuroendocrine tumours were treated with 7.2 GBq (3.5-8.3 GBq) of (177)Lu-DOTATATE on two to five occasions. Planar gamma camera images were acquired at 2, 24, 48 and 168 h post-injection. Whole-body regions of interest were created in the images, and a threshold-based segmentation algorithm was applied to separate the uptake of (177)Lu-DOTATATE into high and low uptake compartments. The conjugate view method was used to quantify the activity, the accumulated activity was calculated and the absorbed dose to the bone marrow was estimated according to the MIRD scheme. Patients were monitored for haematological toxicity based on haemoglobin (Hb), white blood cell (WBC) and platelet (PLT) counts every other week during the treatment period. RESULTS: The mean absorbed dose to the bone marrow was estimated to 0.20 Gy (0.11-0.37 Gy) per 7.4 GBq of (177)Lu-DOTATATE, and the mean dose per fraction correlated with a decrease in Hb (p = 0.01), WBC (p < 0.01) and PLT (p < 0.01) counts. The total mean absorbed dose to the bone marrow was 0.64 Gy (0.30-1.5 Gy) per 24 GBq (8.2-37 GBq) of (177)Lu-DOTATATE and also correlated with a decrease in Hb (p < 0.01), WBC (p = 0.01) and PLT (p < 0.01) counts. CONCLUSIONS: The planar image-based method developed in this study resulted in similar absorbed doses to the bone marrow as reported in earlier studies with blood-based bone marrow dosimetry. The results correlated with haematological toxicity, making it a promising method for estimating bone marrow doses in (177)Lu-DOTATATE treatment without the need for blood and urine sampling.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。