Calibrated automated thrombogram II: removing barriers for thrombin generation measurements

校准型自动血栓图 II:消除凝血酶生成测量的障碍

阅读:1

Abstract

BACKGROUND: Thrombin generation (TG) assessed by Calibrated Automated Thrombogram (CAT-I) reflects the overall capacity of plasma to generate thrombin, thus evaluating the balance between the anti- and procoagulant processes. However, with this method the calibrator curve is usually not measured until completion which has a severe impact on the calculation of the TG parameters, especially under conditions where almost all substrate is consumed. In addition, direct thrombin inhibitor (DTI) cannot be present in the calibration sample due to inhibition of the calibrator. We have developed a modified TG assay (CAT-II) and performed head-to-head comparison with the CAT-I method using the same fluorometer. Furthermore, we have compared our CAT-II method to a new automated TG instrument (ST®-Genesia) using the same calibration method. METHODS: TG was assessed with CAT-I and CAT-II using the same fulorometer and with ST®-Genesia in control plasma and plasma containing different anticoagulants (dabigatran, rivaroxaban, apixaban) and plasmas to which common interfering substances, bilirubin, hemoglobin and lipids were added. In CAT-I, calibration was against the same plasma containing calibrator in the presence of fluorogenic substrate (Z-GGR-AMC). In contrast, CAT-II method and ST®-Genesia used a standard concentration of thrombin in buffer and 7-amino-4-methylcoumarin (AMC) in a separate plasma sample for calibration. RESULTS: TG obtained from CAT-I using anticoagulant-free plasmas was lower compared with TG from CAT-II but both methods demonstrated an intra-assay variation less than 5% on all measured parameters. When comparing the two different calibration methods in the presence of different anticoagulants, a high correlation was seen in the presence of rivaroxaban and apixaban (R(2) > 0.97), but not with dabigatran, a direct thrombin inhibitor. CAT-II method showed dose-dependent inhibition of TG in the presence of dabigatran, while CAT-I was not able to detect it. Both methods were able to correct for the interfering substances. CONCLUSIONS: Our results showed high similarity between the results of CAT-I and CAT-II method when it is applied in control plasmas and plasmas not inhibited with a direct thrombin inhibitor. Furthermore, both the CAT-II method and ST-Genesia using the same calibration method were able to detect the effect of all oral anticoagulants. Taken together, applying a new calibration method is a significant improvement for monitoring patients on direct thrombin inhibitors while not introducing any bias to results obtained on other types of samples.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。