Predictive utility of the impedance drop on AF recurrence using digital intraprocedural data linked to electronic health record data

利用与电子健康记录数据关联的数字术中数据预测阻抗下降对房颤复发的影响

阅读:4

Abstract

BACKGROUND: Local impedance drop in cardiac tissue during catheter ablation may be a valuable measure to guide atrial fibrillation (AF) ablation procedures for greater effectiveness. OBJECTIVE: The study sought to assess whether local impedance drop during catheter ablation to treat AF predicts 1-year AF recurrence and what threshold of impedance drop is most predictive. METHODS: We identified patients with AF undergoing catheter ablation in the Mercy healthcare system. We downloaded AF ablation procedural data recorded by the CARTO system from a cloud-based analytical tool (CARTONET) and linked them to individual patient electronic health records. Average impedance drops in anatomical region of right and left pulmonary veins were calculated. Effectiveness was measured by a composite outcome of repeat ablation, AF rehospitalization, direct current cardioversion, or initialization of a new antiarrhythmic drug post-blanking period. The association between impedance drop and 1-year AF recurrence was assessed by logistic regression adjusting for demographics, clinical, and ablation characteristics. Bootstrapping was used to determine the most predictive threshold for impedance drop based on the Youden index. RESULTS: Among 242 patients, 23.6% (n = 57) experienced 1-year AF recurrence. Patients in the lower third vs upper third of average impedance drop had a 5.9-fold (95% confidence interval [CI] 1.81-21.8) higher risk of recurrence (37.0% vs 12.5%). The threshold of 7.2 Ω (95% CI 5.75-7.7 Ω) impedance drop best predicted AF recurrence, with sensitivity of 0.73 and positive predictive value of 0.33. Patients with impedance drop ≤7.2 Ω had 3.5-fold (95% CI 1.39-9.50) higher risk of recurrence than patients with impedance drop >7.2 Ω, and there was no statistical difference in adverse events between the 2 groups of patients. Sensitivity analysis on right and left wide antral circumferential ablation impedance drop was consistent. CONCLUSION: Average impedance drop is a strong predictor of clinical success in reducing AF recurrence but as a single criterion for predicting recurrence only reached 73% sensitivity and 33% positive predictive value.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。