Targeted Ultrasound Contrast Imaging of Tumor Vasculature With Positively Charged Microbubbles

利用带正电荷的微泡进行肿瘤血管靶向超声造影成像

阅读:1

Abstract

PURPOSE: Molecular ultrasound imaging of tumor vasculature is being actively investigated with microbubble contrast agents targeted to neovasculature biomarkers. Yet, a universal method of targeting tumor vasculature independent of specific biomarkers, or in their absence, would be desirable. We report the use of electrostatic interaction to achieve adherence of microbubbles to tumor vasculature and resulting tumor delineation by ultrasound imaging. METHODS AND MATERIALS: Microbubbles were prepared from decafluorobutane gas by amalgamation of aqueous micellar medium. Distearoyl phosphatidylcholine (DSPC) and polyethylene glycol (PEG)-stearate were used as microbubble shell-forming lipids; cationic lipid distearoyl trimethylammoniumpropane (DSTAP) was included to introduce positive electrostatic charge. Microbubbles were subjected to flotation in normal gravity, to remove larger particles. Murine colon adenocarcinoma tumor (MC38, J. Schlom, National Institutes of Health) was inoculated in the hind leg of C57BL/6 mice. Contrast ultrasound imaging was performed under isoflurane anesthesia, using a clinical imaging system in low power mode, with tissue signal suppression (contrast pulse sequencing, 7 MHz, 1 Hz; Mechanical Index, 0.2). The ultrasound probe was positioned to monitor the tumor and contralateral leg muscle; microbubble contrast signal was monitored for 30 minutes or more, after intravenous bolus administration of 2.10 microbubbles. Individual time point frames were extracted from ultrasound video recording and analyzed with ImageJ. RESULTS: Mean bubble diameter was ~1.6 to 2 μm; 99.9% were less than 5 μm, to prevent blocking blood flow in capillaries. For cationic DSTAP-carrying microbubbles, contrast signal was observed in the tumor beyond 30 minutes after injection. As the fraction of positively charged lipid in the bubble shell was increased, adherent contrast signal in the tumor also increased, but accumulation of DSTAP-microbubbles in the normal muscle increased as well. For bubbles with the highest positive charge tested, DSTAP-DSPC molar ratio 1:4, at 10 minutes after intravenous administration of microbubbles, the contrast signal difference between the tumor and normal muscle was 1.5 (P < 0.005). At 30 minutes, tumor/muscle contrast signal ratio improved and reached 2.1. For the DSTAP-DSPC 1:13 preparation, tumor/muscle signal ratio exceeded 3.6 at 10 minutes and reached 5.4 at 30 minutes. Microbubbles with DSTAP-DSPC ratio 1:22 were optimal for tumor targeting: at 10 minutes, tumor/muscle signal ratio was greater than 7 (P < 0.005); at 30 minutes, greater than 16 (P < 0.01), sufficient for tumor delineation. CONCLUSIONS: Cationic microbubbles are easy to prepare. They selectively accumulate in the tumor vasculature after intravenous administration. These microbubbles provide target-to-control contrast ratio that can exceed an order of magnitude. Adherent microbubbles delineate the tumor mass at extended time points, at 30 minutes and beyond. This may allow for an extension of the contrast ultrasound examination time. Overall, positively charged microbubbles could become a universal ultrasound contrast agent for cancer imaging.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。