Balanced Steady-State Free Precession Enables High-Resolution Dynamic 3D Deuterium Metabolic Imaging of the Human Brain at 7T

平衡稳态自由进动技术可在7T磁场下实现人脑高分辨率动态三维氘代谢成像。

阅读:3

Abstract

OBJECTIVES: Deuterium ( 2 H) metabolic imaging (DMI) is an emerging magnetic resonance technique to non-invasively map human brain glucose (Glc) uptake and downstream metabolism following oral or intravenous administration of 2 H-labeled Glc. The achievable spatial resolution is limited due to inherently low sensitivity of DMI. This hinders potential clinical translation. The purpose of this study was to improve the signal-to-noise ratio (SNR) of 3D DMI via a balanced steady-state free precession (bSSFP) acquisition scheme combined with fast non-Cartesian spatial-spectral sampling to enable high-resolution dynamic imaging of neural Glc uptake and glutamate+glutamine (Glx) synthesis of the human brain at 7T. MATERIALS AND METHODS: Six healthy volunteers (2 f/4 m) were scanned after oral administration of 0.8 g/kg [6,6']- 2 H-Glc using a novel density-weighted bSSFP acquisition scheme combined with fast 3D concentric ring trajectory (CRT) k-space sampling at 7T. Time-resolved whole brain DMI datasets were acquired for approximately 80 minutes (7 minutes per dataset) after oral 2 H-labeled Glc administration with 0.75 mL and 0.36 mL isotropic spatial resolution and results were compared to conventional spoiled Free Induction Decay (FID) 2 H-MRSI with CRT readout at matched nominal spatial resolution. Dynamic DMI measurements of the brain were accompanied by simultaneous systemic Glc measurements of the interstitial fluid using a continuous Glc monitoring (CGM) sensor (on the upper arm). The correlation between brain and interstitial Glc levels was analyzed using linear mixed models. RESULTS: The bSSFP-CRT approach achieved SNRs that were up to 3-fold higher than conventional spoiled FID-CRT 2 H-MRSI. This enabled a 2-fold higher spatial resolution. Seventy minutes after oral tracer uptake comparable 2 H-Glc, 2 H-Glx, and 2 H-water concentrations were detected using both acquisition schemes at both, regular and high spatial resolutions (0.75 ml and 0.36 mL isotropic). The mean Areas Under the Curve (AUC) for interstitial fluid Glc measurements obtained using a CGM sensor was 509 ± 65 mM·min. This is 3.4 times higher than the mean AUC of brain Glc measurements of 149 ± 43 mM·min obtained via DMI. The linear mixed models fitted to assess the relationship between CGM measures and brain 2 H-Glc yielded statistically significant slope estimates in both GM (β 1  = 0.47, P  = 0.01) and WM (β 1  = 0.36, P  = 0.03). CONCLUSIONS: In this study we successfully implemented a balanced steady-state free precession (bSSFP) acquisition scheme for dynamic whole-brain human DMI at 7T. A 3-fold SNR increase compared to conventional spoiled acquisition allowed us to double the spatial resolution achieved using conventional FID-CRT DMI. Systemic continuous glucose measurements, combined with dynamic DMI, demonstrate significant potential for clinical applications. This could help improve our understanding of brain glucose metabolism by linking it to time-resolved peripheral glucose levels. Importantly, these measurements are conducted in a minimally invasive and physiological manner.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。