Development and clinical application of extendable prostheses in limb salvage surgery for primary malignant bone tumours in children : a systematic review of functional outcomes and complications

儿童原发性恶性骨肿瘤肢体挽救手术中可伸缩假体的研发及临床应用:功能结果和并发症的系统评价

阅读:2

Abstract

AIMS: Extendable prostheses have developed rapidly over the decades to solve limb length discrepancy (LLD) following limb salvage surgery in children and adolescents who have suffered primary malignant bone tumours. In this study, we performed a systematic review of the literature on extendable prostheses to investigate their developments and clinical outcomes, to provide evidence-based recommendations for enhancing clinical implementation and refinement. METHODS: A systematic review of 46 studies with 709 invasive cases and 556 noninvasive cases was performed after searching the PubMed, EMBASE, and Web of Science databases. Results of the prosthesis survival rate, functional outcomes, and complications were extracted, recategorized, and analyzed. RESULTS: With the increase in publication year, there was no significant change in the five-year prosthesis survival rate, while the Musculoskeletal Tumour Society (MSTS) score exhibited an upward trend. Apart from infection, the incidence of mechanical complications increased as follow-up time extended. Failed structure of invasive prosthesis was higher than in those who received a noninvasive extendable prosthesis (25.1% (123/491) vs 15.0% (70/466); p < 0.001, Power = 0.972). The mean number of additional procedures in patients who received an invasive prosthesis was higher than those who received a noninvasive extendable prosthesis (2.4 (1.3 to 3.4) vs 1.4 (0.1 to 2.7); p = 0.021), and there was no obvious clinical difference between invasive prostheses and noninvasive prostheses in infection (15.0% (88/586) vs 13.4% (68/508); p = 0.442, Power = 0.125). Infection (44/361, 12.2%) was the most common complication associated with the Stanmore JTS prosthesis, while the incidence of aseptic loosening (14/296, 4.7%) was the lowest. The mean incidence of complications in the Stanmore Mark I-IV group was higher than that in the Stanmore JTS group (68.9% (104/151) vs 36.6% (49/134); p < 0.001, Power = 0.9998). CONCLUSION: Despite decades of progress, extendable prostheses have shown promising results but still face challenges such as high infection rates, requiring further technological innovation for better outcomes.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。