Effectiveness of a Non-Taped Compression Dress in Patients Receiving Cardiac Implantable Electronic Devices

非胶带式加压衣对接受心脏植入式电子设备患者疗效的研究

阅读:1

Abstract

BACKGROUND: Hematoma and skin damage are not uncommon after cardiac implantable electronic device (CIED) placement. The use of conventional hemostatic gauze and tape seems to be suboptimal in controlling these complications. This study aimed to evaluate the impact of a novel compression dress with a special pad and elastic bands for postoperative care. METHODS: A total of 175 CIED recipients were randomly divided into two groups: an experimental group with 85 patients who used a non-taped compression dress and a control group with 90 patients who used conventional gauze ball and elastic tapes. Skin integrity, hematoma, and oozing were compared between these two groups within 7 days after surgery. RESULTS: The mean age of the patients was 71.2 ± 13.3 years, and 83 (47.4%) were male. The results of the experimental vs. control group were as follows: skin integrity - 96.5% vs. 86.7% (p < 0.05); hematoma - 0% vs. 7.8% (p < 0.05); and oozing - 1.2% vs. 7.8% (p < 0.05). All observed endpoints were better in the experimental group. CONCLUSIONS: The use of a non-taped compression dress was associated with less unfavorable outcomes in terms of skin integrity and hemostasis.