Balloon Aortic Valvuloplasty in a Premature Neonate with Critical Aortic Valve Stenosis Weighing 1493 g

对一名体重1493克的早产新生儿进行球囊主动脉瓣成形术,该患儿患有严重的主动脉瓣狭窄。

阅读:1

Abstract

The use of balloon aortic valvuloplasty for congenital aortic valve stenosis was well established in literatures. However, balloon aortic valvuloplasty performed in low body weight neonates had been infrequently reported. Here we report a 5-day-old premature neonate diagnosed critical aortic valve stenosis. Balloon aortic valvuloplasty was performed as first-line therapy while the patient weighed only 1493 g. Balloon aortic valvuloplasty went successfully with transvalvular pressure gradient decreased from 80 mmHg to 44 mmHg. Aortic regurgitation after balloon aortic valvuloplasty was mild. The patient's clinical condition stabilized after balloon aortic valvuloplasty and was able to gain weight to 2665 g. Our report demonstrates that balloon aortic valvuloplasty is possible, safe and efficient as first-line approach for critical aortic valve stenosis in neonates with low body weight.