ANTEGRADE NAILING VERSUS LOCKING PLATE OF 2-AND 3-PART PROXIMAL HUMERUS FRACTURES

肱骨近端二段及三段骨折的髓内钉固定与锁定钢板固定比较

阅读:1

Abstract

OBJECTIVE: To evaluate and compare the proportions of complications and radiographic findings of osteosynthesis of 2- and 3-part proximal humerus fractures with two methods of treatment: third-generation antegrade nailing and locking plate. METHODS: 46 patients with a mean age of 58.9 ± 16.6 years between January 2020 and January 2021 were evaluated. In sixteen cases (34.8%), antegrade nailing was used, and in thirty cases (65, 2%), a locking proximal humerus plate. The method used included the rate of complications with a minimum follow-up of 6 months after surgery and radiographic evaluation. RESULTS: There was no difference between the groups regarding the proportion of complications (nail group 18.8%, plate group 13.3%; p = 0.681). The nail group had less residual varus loss (cervicodiaphyseal angle nail group with 132.1º ± 2.3º, plate group 123.8º ± 10.1º; p < 0.001). In the plate group, women had the lowest value (1.43 ± 0.22) of the deltoid tuberosity index (DTI) compared to men (1.58 ± 0.11) (p = 0.022). CONCLUSION: Osteosynthesis, with a locking plate and antegrade nailing, did not show differences in the proportion of complications. The nail group had less change in the postoperative cervicodiaphyseal angle, however, there were two serious complications with screw cut-out and varus deviation, requiring surgical reapproach. Level of Evidence II, Retrospective Observational Study.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。