ASSESSMENT OF REPRODUCIBILITY OF SANDERS CLASSIFICATION FOR CALCANEAL FRACTURES

桑德斯分型法在跟骨骨折中的可重复性评估

阅读:1

Abstract

OBJECTIVE: : To assess intra- and interobserver reproducibility of Sanders Classification System of calcaneal fractures among experienced and less experienced observers. METHODS: : Forty-six CT scans of intra-articular calcaneal fractures were reviewed. Four observers, two with ten years of experience in foot and ankle surgery and two third-year residents in Orthopedics and Traumatology classified the fractures on two separate occasions three weeks apart from each other. The intra and inter-observer reliability was analyzed using the Kappa index. RESULTS: : There was good intraobserver reliability for the two experienced observers and one less experienced observer (Kappa values 0.640, 0.632 and 0.629, respectively). The interobserver reliability was fair between the experienced observers (Kappa = 0.289) and moderate among the less experienced observers (Kappa = 0.527). CONCLUSIONS: : The Sanders Classification System showed good intraobserver reliability, but interobserver reproducibility below the ideal level, both among experienced and less experienced observers. Level of Evidence III, Diagnostic Studies.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。