Intraoperative electrocorticography for physiological research in movement disorders: principles and experience in 200 cases

术中皮层脑电图在运动障碍生理学研究中的应用:原理及200例病例经验

阅读:1

Abstract

OBJECTIVE Contemporary theories of the pathophysiology of movement disorders emphasize abnormal oscillatory activity in basal ganglia-thalamocortical loops, but these have been studied in humans mainly using depth recordings. Recording from the surface of the cortex using electrocorticography (ECoG) provides a much higher amplitude signal than depth recordings, is less susceptible to deep brain stimulation (DBS) artifacts, and yields a surrogate measure of population spiking via "broadband gamma" (50-200 Hz) activity. Therefore, a technical approach to movement disorders surgery was developed that employs intraoperative ECoG as a research tool. METHODS One hundred eighty-eight patients undergoing DBS for the treatment of movement disorders were studied under an institutional review board-approved protocol. Through the standard bur hole exposure that is clinically indicated for DBS lead insertion, a strip electrode (6 or 28 contacts) was inserted to cover the primary motor or prefrontal cortical areas. Localization was confirmed by the reversal of the somatosensory evoked potential and intraoperative CT or 2D fluoroscopy. The ECoG potentials were recorded at rest and during a variety of tasks and analyzed offline in the frequency domain, focusing on activity between 3 and 200 Hz. Strips were removed prior to closure. Postoperative MRI was inspected for edema, signal change, or hematoma that could be related to the placement of the ECoG strip. RESULTS One hundred ninety-eight (99%) strips were successfully placed. Two ECoG placements were aborted due to resistance during the attempted passage of the electrode. Perioperative surgical complications occurred in 8 patients, including 5 hardware infections, 1 delayed chronic subdural hematoma requiring evacuation, 1 intraparenchymal hematoma, and 1 venous infarction distant from the site of the recording. None of these appeared to be directly related to the use of ECoG. CONCLUSIONS Intraoperative ECoG has long been used in neurosurgery for functional mapping and localization of seizure foci. As applied during DBS surgery, it has become an important research tool for understanding the brain networks in movement disorders and the mechanisms of therapeutic stimulation. In experienced hands, the technique appears to add minimal risk to surgery.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。