Subthalamic nucleus deep brain stimulator placement using high-field interventional magnetic resonance imaging and a skull-mounted aiming device: technique and application accuracy

利用高场介入磁共振成像和颅骨固定式瞄准装置进行丘脑底核深部脑刺激器植入:技术和应用精度

阅读:1

Abstract

OBJECT: The authors discuss their method for placement of deep brain stimulation (DBS) electrodes using interventional MR (iMR) imaging and report on the accuracy of the technique, its initial clinical efficacy, and associated complications in a consecutive series of subthalamic nucleus (STN) DBS implants to treat Parkinson disease (PD). METHODS: A skull-mounted aiming device (Medtronic NexFrame) was used in conjunction with real-time MR imaging (Philips Intera 1.5T). Preoperative imaging, DBS implantation, and postimplantation MR imaging were integrated into a single procedure performed with the patient in a state of general anesthesia. Accuracy of implantation was assessed using 2 types of measurements: the "radial error," defined as the scalar distance between the location of the intended target and the actual location of the guidance sheath in the axial plane 4 mm inferior to the commissures, and the "tip error," defined as the vector distance between the expected anterior commissure-posterior commissure (AC-PC) coordinates of the permanent DBS lead tip and the actual AC-PC coordinates of the lead tip. Clinical outcome was assessed using the Unified Parkinson's Disease Rating Scale part III (UPDRS III), in the off-medication state. RESULTS: Twenty-nine patients with PD underwent iMR imaging-guided placement of 53 DBS electrodes into the STN. The mean (+/- SD) radial error was 1.2 +/- 0.65 mm, and the mean absolute tip error was 2.2 +/- 0.92 mm. The tip error was significantly smaller than for STN DBS electrodes implanted using traditional frame-based stereotaxy (3.1 +/- 1.41 mm). Eighty-seven percent of leads were placed with a single brain penetration. No hematomas were visible on MR images. Two device infections occurred early in the series. In bilaterally implanted patients, the mean improvement on the UPDRS III at 9 months postimplantation was 60%. CONCLUSIONS: The authors' technical approach to placement of DBS electrodes adapts the procedure to a standard configuration 1.5-T diagnostic MR imaging scanner in a radiology suite. This method simplifies DBS implantation by eliminating the use of the traditional stereotactic frame and the subsequent requirement for registration of the brain in stereotactic space and the need for physiological recording and patient cooperation. This method has improved accuracy compared with that of anatomical guidance using standard frame-based stereotaxy in conjunction with preoperative MR imaging.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。