TIP, TORQUE & ROTATIONS: How accurately do digital superimposition software packages quantify tooth movement?

倾斜、扭矩和旋转:数字叠加软件包对牙齿移动的量化精度如何?

阅读:1

Abstract

BACKGROUND: To investigate the accuracy of three different 3D digital model registration software for tip, torque and rotation measurements, with reference to a 3D digital virtual setup. Twenty maxillary and mandibular pre-treatment scans of patients undergoing clear aligner therapy were used. Digital setups were generated from pre-treatment scans using a tooth movement software. Both the pretreatment digital scans (T1) and digital setups (T2) were converted to STL files to be exported to the 3 studied software that employed: (1) Semiautomatic best fit registration (S-BF), (2) Interactive surface-based registration (I-SB), and (3) Automatic best fit registration (A-BF) respectively. Changes in tip, torque and rotation were calculated for all the registered pairs. RESULTS: The change in tooth position was compared between the calculated tooth movement using each of the registration software packages versus the actual generated tooth movement from the digital setups. Continuous data was expressed as mean and standard deviation. Intra Class Correlation Coefficient for agreement between digital simulation and each software was used. Intra and Inter-examiner reliabilities were also assessed using Intra Class Correlation Coefficient. Significance of the obtained results was expressed at p ≤ 0.01. Semiautomatic best fit registration software showed excellent agreement (> 0.90) for all tooth movements, except for good agreement for torque (0.808). Interactive surface-based registration software showed moderate agreement for all measurements (0.50 and < 0.75), except for good agreement for rotation (0.783). Automatic best fit registration software demonstrated excellent agreement (> 0.90) for rotation, good agreement for tip (0.890) and moderate agreement for torque (0.740). CONCLUSIONS: Overall, semiautomatic best fit registration software consistently showed excellent agreement in superimpositions compared to other software types. Automatic best fit registration software consistently demonstrated better agreement for mandibular superimpositions, compared to others. Accuracy of digital model superimpositions for tooth movements studied in superimposition studies, can be attributed to the algorithm employed for quantification.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。