The difference of stress distribution of maxillary expansion using rapid maxillary expander (RME) and maxillary skeletal expander (MSE)-a finite element analysis

快速上颌扩张器(RME)与上颌骨扩张器(MSE)上颌扩张应力分布差异的有限元分析

阅读:1

Abstract

BACKGROUND: Maxillary skeletal expander (MSE) in combination with miniscrews was developed to overcome the drawbacks that may have resulted from the application of conventional rapid maxillary expander (RME). This research was conducted to analyze the difference of stress distribution of maxillary expansion using RME and MSE in the region of interests (ROIs): first molars (M1), palatal alveolar bones of M1, palatine sutures, zygomatic sutures, miniscrews, and their surrounding bones. METHODS: A dry skull was scanned using CBCT and rendered into a three-dimensional (3D) model of craniomaxillary structures. The data analysis was done both visually and numerically. RESULT: The stress distributions in RME group were located at the palatal side of M1, mesial side of palatal alveolar of M1, pulp chamber of M1, and inferior cortex of palatine sutures. The stress distributions in the MSE group were located at the distopalatal cusp of M1, palatal side of palatal alveolar of M1, and inferior and superior cortex of palatine sutures. The stress distributions in zygomatic sutures on both groups were located at the zygomaticotemporal sutures, whereas in the miniscrews, the stress were located at the anterior miniscrews and palatal side of surrounding bones. CONCLUSIONS: There were significant differences of stress distribution of maxillary expansion measured in the ROIs in the craniomaxillary 3D model using RME and MSE.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。