Comparison of shear bond strength and adhesive remnant index between precoated and conventionally bonded orthodontic brackets

预涂层正畸托槽与传统粘接正畸托槽剪切粘接强度和粘接剂残留指数的比较

阅读:1

Abstract

BACKGROUND: The purpose of this study was to compare the shear bond strength and adhesive remnant index (ARI) at the enamel-bonding interface of precoated and conventionally bonded brackets, utilizing standardized procedures. METHODS: The test sample consisted of 90 recently extracted bovine permanent mandibular incisors. The teeth were bonded using the same protocol and were tested in three different situations. A material testing systems machine was utilized for debonding, and the remaining adhesive on the tooth was recorded. RESULTS: Immediately after bonding, we found that the shear bond strength of the precoated brackets (6.27 MPa) was significantly higher than that of conventional brackets (5.37 MPa) (p<0.05). However, no significant differences in bond strength were found between the two bracket systems after 24 h of bonding or after thermocycling. The conventional brackets had higher ARI scores than the precoated bracket systems immediately after bonding and after 24 h. CONCLUSIONS: Since there were no significant differences in the bonding strength after 24 h, the immediate bonding strength of the precoated brackets during the first day does not appear to be a major advantage over the conventional bracket systems. However, less adhesive on the tooth after debonding is an advantage of precoated brackets.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。