Efficacy and safety of low power holmium laser enucleation of the prostate: A prospective short- and medium-term single-blind randomized trial

低功率钬激光前列腺剜除术的疗效和安全性:一项前瞻性短期和中期单盲随机试验

阅读:1

Abstract

PURPOSE: We evaluated the efficacy and safety of mid-term follow-up in low-power (LP) Holmium laser enucleation of the prostate (HoLEP) compared with high-power (HP) surgery for benign prostatic hyperplasia (BPH). MATERIALS AND METHODS: This prospective, single-blind, randomized controlled study was conducted between September 2020 and April 2021. Ninety male patients >50 years who underwent HoLEP for BPH were randomly assigned to HP (80 W/2 J/40 Hz) and LP (24 W/2 J/12 Hz) groups. The primary endpoint was the total International Prostate Symptom Score (IPSS) six months after surgery. The secondary endpoints were perioperative results and postoperative outcomes at two weeks, three and six months after the surgery, including Clavien-Dindo complication classification. RESULTS: At six months after HoLEP, 41 and 42 patients were followed up in the HP and LP groups, respectively. There was no difference in the preoperative characteristics between the two groups. The prostate volumes were 67.1±23.7 mL for the HP group and 64.3±25.7 mL for the LP group (p=0.592), respectively. Although the total operative time was significantly longer by 13.1 minutes in the LP group (47.8±20.3 min vs. 60.9±23.3 min, p=0.006), the total delivered energy was significantly lower, which was only about 68% of the HP group (58.2±23.9 kJ vs. 39.9±13.2 kJ, p<0.001). Surgical outcomes significantly improved postoperatively in both groups compared to baseline, except for storage symptoms. Improvement in IPSS storage subscore was observed from the immediate postoperative 2 weeks in the LP group (8.1±3.1 to 6.9±3.8, p<0.001), whereas there was no significant recovery in the HP group (8.0±3.2 to 7.7±3.4, p=0.842). In the 6-month follow, there was no significant difference between the two groups in the IPSS total score (5.9±5.6 vs. 7.3±5.3, p=0.260) as well as IPSS storage subscore. In addition, there was no significant difference in postoperative complications, including bleeding or urinary incontinence, between the two groups. CONCLUSIONS: The HoLEP procedure performed using an LP laser device resulted in lower total delivered energy, faster recovery, and significantly improved surgical outcomes up to mid-term follow-up. There was no difference in efficiency or safety between the HP device system.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。