Effect of Er,Cr:YSGG laser with a side-firing tip on decontamination of titanium disc surface: an in vitro and in vivo study

侧射式Er,Cr:YSGG激光器对钛盘表面去污效果的体外和体内研究

阅读:1

Abstract

PURPOSE: To evaluate the effectiveness of an erbium, chromium:yttrium-scandium-gallium-garnet (Er,Cr:YSGG) laser with side-firing tip in decontamination of titanium (Ti) disc. METHODS: In the first test series, 29 Ti-discs were contaminated with Staphylococcus aureus and treated as follows: positive control (no treatment); Perioflow; Laser A (0.75 W, 100 Hz), Laser B (1.5 W, 30 Hz); Laser C (no radiation, 60% water); and Laser D (no radiation, 50% water). For bacterial quantification, colony forming units (CFU, vital cells only) and quantitative PCR (qPCR, vital and devital cells) were performed. In a second test series, 92 Ti-discs were used, contaminated with in vivo-grown biofilm and treated as follows: positive control (no treatment); Perioflow; Laser E (1.5 W, 30 Hz), and Laser F (no radiation, 50% water). Considering the different and unknown culture conditions, quantification of bacteria was performed by broad-spectrum bacterial qPCR only. Based on the assumption that all cells of an organism contain an equivalent complement of genetic information, genome equivalent (GE) determination ensured the detection of the different intact and semi-intact genomes, regardless of type of bacterial species and vitality, circumvent the inherent bias of cultures. RESULTS: The GE values were significantly reduced by all interventions in both test series, compared to the positive control group (p < 0.001). In the first test series with S. aureus as model organism, Perioflow yielded a lower GE than the Laser groups A-D (all p < 0.025). The number of CFUs was significantly reduced in the intervention groups compared to the positive control (p < 0.001), except for Laser A (p = 0.157) and Laser D (p = 0.393). In the second test series, none of the pairwise comparisons of the intervention conditions showed a significant difference (Perioflow vs. Laser E: p = 0.732; Perioflow vs. Laser F: p = 0.590; Laser E vs. Laser F: p = 0.379). CONCLUSION: The Er,Cr:YSGG laser with side-firing tip and Perioflow were equally capable of effectively decontaminating a Ti-disc surface. It is assumed that the bacterial reduction was largely due to the mechanical effect of the air and water stream.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。