Computer-assisted implant placement and full-arch immediate loading with digitally prefabricated provisional prostheses without cast: a prospective pilot cohort study

计算机辅助种植体植入和全牙弓即刻负重,采用数字化预制临时义齿,无需石膏模型:一项前瞻性试点队列研究

阅读:1

Abstract

BACKGROUND: Immediate loading of implant-supported full-arch rehabilitations has become routine practice when treating edentulous patients. The combination of static computer-aided implant surgery (s-CAIS) and digital prosthetic workflow could eliminate several treatment steps and facilitate prostheses delivery. The aim of this study is to evaluate the 1-year results of digitally prefabricated polymethyl methacrylate (PMMA) provisional prostheses without a cast for full-arch computer-assisted immediate loading. MATERIALS AND METHODS: A digital pre-operative treatment planning was realized for all patients: dental implants and screw-retained abutments were selected in the planning software and two surgical templates were fabricated for each patient. The first template was mucosa or teeth-supported to drill the holes for fixating pins, while the second template was placed after raising a full-thickness flap and was supported by pins as well as soft or hard tissue distal support. Furthermore, based on the surgical planning, interim prostheses were digitally designed and milled of PMMA resin blocks with subsequent pink resin veneering. Osteotomies and implant placement were performed through the surgical guides and all implants were immediately loaded with prefabricated full-arch interim prostheses directly connected to titanium copings with a flowable resin. RESULTS: A total of 55 dental implants were placed in ten patients. In all cases, interim prostheses allowed the insertion of titanium copings without the need of access hole enlargement or adaptation. All the prostheses had 1 year of functional loading to simulate the long provisional phase. No screw loosening occurred at the first removal of the prostheses after implant osseointegration. No fracture occurred during the whole period. After 1 year, the mean marginal bone loss level was 0.37 ± 0.06 mm, while the implant survival rate was 98.18% (n=54/55), with just one implant failing but not affecting final prosthesis delivery to the patient. CONCLUSIONS: Within the limitations of the present study, the authors concluded that digitally prefabricated provisional prostheses for full-arch immediate loading with s-CAIS could be a valid alternative treatment modality. Milled PMMA restorations proved to be durable enough during the long provisional phase, without prosthetic complications.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。