Comparison of access-hole filling materials for screw retained implant prostheses: 12-month in vivo study

螺钉固位种植义齿开口填充材料的比较:一项为期12个月的体内研究

阅读:1

Abstract

BACKGROUND: Screw retained implant prostheses seem to be an efficient restorative method to prevent peri-implantitis caused by cement excess around the abutment. The drawback of the screw-retained prostheses is the difficulty to realize an efficient access-hole filling functionally and aesthetically. Up to now, few in vitro and in vivo studies were reported in the literature. The aim of this study was to evaluate clinical performances of two direct filling materials through a period of 12 months. METHODS: To pursue a previous in vitro evaluation, this in vivo 12 months prospective study followed up and compared the access-hole filling integrity of a modified 4-META (4-methacryloxyethyl trimellitate anhydride)/MMA-TBB (methyl methacrylate-tri-n-butyl borane) - based resin (M4M) and a photo-polymerizing nano-hybrid composite resin (CR). Twenty-eight access-holes were filled with both materials respectively, then impressions and intra-oral photographs were taken at T = 0, T = 1 M (month), 3, 6, and 12 M. The access-hole surface measurement and the margin analysis (depth and angle) were carried out. The VAS (visual analogue scale) value on marginal discoloration and integrity at the baseline T = 0 and T = 12 M was recorded. RESULTS: The mean values of the surface areas changes from T = 1 to T = 12 M were 83.3 ± 11.5% for group CR and 77.1 ± 13.1% for group M4M, respectively. (Mann-Whitney test p < 0.05, p = 0.046). The mean marginal depth at T = 12 M for group CR were 141.2 ± 125.5 μm and 132.1 ± 107.8 μm for the group M4M, respectively. (Mann-Whitney test p > 0.05, p = 0.58). The mean values of the angle formed at the margin (T = 12 M) were for group CR 39.5 ± 19.4° and 28.2 ± 17.2° for group M4M, respectively (Mann-Whitney test p < 0.0001). The photographical analysis by VAS values showed no significant difference between CR and M4M groups (Mann-Whitney test p > 0.05, p = 0.848). CONCLUSIONS: Based on intra- and extra-oral evaluations with the limitation, both CR and M4M combined with a ceramic primer are indicated as promising materials to fill the access-hole. Further long-term investigation is necessary to confirm this finding.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。