Viscoelasticity of packed erythrocyte suspensions subjected to low amplitude oscillatory deformation

低振幅振荡变形下红细胞悬浮液的粘弹性

阅读:1

Abstract

Concentrated adult erythrocyte suspensions were subjected to low amplitude oscillatory shear in a Weissenberg rheogoniometer equipped with a cone-and-plate assembly. The dynamic viscoelastic properties of the suspension were measured over a broad range of frequency by a numerical solution that accounted for fluid inertia. Variation of shear amplitude and cell volume percent, and comparison of buffered saline, plasma, and dextran as suspending media showed that the cellular elements had undergone small bending and shearing deformations. Studies of normal adult erythrocytes, hypotonically swollen cells, temperature-altered cells, and erythrocyte ghosts suggested that the method was evaluating membrane material properties. The normal membrane was found to exhibit a shear rate dependent elastic modulus that increased by more than a factor of 20 over a frequency range from 0.0076 Hz to 60 Hz. The membrane viscosity showed a substantial drop with frequency indicative of a frequency thinning phenomenon. At high frequency of deformation the viscous response of normal erythrocytes was no longer indicative of a membrane property due to the dominant influence of the internal hemoglobin solution. The studies generally supported the ability of the method to quantify relative membrane material properties and detect changes in membrane structure.