Abstract
BACKGROUND: Evaluation of the transverse sinus stenosis (TSS) is essential for TSS-related diseases. OBJECTIVE: To investigate a new method for the quantitative assessment of TSS based on the correlation between TSS and trans-stenotic pressure gradient (TPG). METHODS: Patients with unilateral pulsatile tinnitus with or without idiopathic intracranial hypertension were retrospectively included. All patients underwent CT venography and venous manometry and were confirmed to have TSS. The cross-sectional diameter/area of TSS, the poststenotic and prestenotic segments, and the superior sagittal sinus (SSS) were measured. The degree of TSS was calculated by dividing the diameter/area of TSS by the diameter/area of the poststenotic segment (M1/M2), prestenotic segment (M3/M4), and SSS (M5/M6). Partial correlation analysis (controlling for the effect of age, sex, outflow laterality, and contralateral stenosis) was performed to evaluate the correlation between M1-M6 and the TPG. Receiver operating characteristic curve analysis of M1-M6 for diagnosing a significant TPG (≥8 mm Hg) was performed. RESULTS: Ninety-nine patients met the inclusion criteria. The partial correlation coefficients between M1-M6 and the TPG were 0.60, 0.61, 0.43, 0.48, 0.39, and 0.54, respectively. The areas under the curve (AUCs) of M1-M6 for diagnosing a significant TPG were 0.81, 0.86, 0.68, 0.69, 0.64, and 0.72, respectively. The AUC of M2 was significantly larger than that of M3 (P=0.002), M4 (P<0.001), M5 (P=0.001), and M6 (P<0.001). CONCLUSIONS: Quantitatively assessing TSS by taking the ratio of the cross-sectional area of TSS to that of the poststenotic segment might be a more efficient method for predicting the TPG.