Description of Noise Levels in a Pharmacy Department at a University Hospital

大学医院药房部门噪音水平描述

阅读:1

Abstract

OBJECTIVE: Few data are available regarding noise levels in hospital pharmacies. This study mainly aimed to assess noise levels in different areas and during various activities in the pharmacy department of a tertiary care hospital affiliated with Université de Montréal in Canada and identify potential noise sources. MATERIALS AND METHODS: This cross-sectional descriptive study was conducted in the pharmacy department of Centre Hospitalier Universitaire (CHU) Sainte-Justine. A convenience sample of 30 sites was established to encompass various activities. Noise levels were measured with a sound level meter for three types of activity: office activities, storage, and drug preparation. Noise measurements were conducted for a 1-day period at each site. RESULTS: The average noise level ranged from 41.9 ± 3.4 dBA to 71.4 ± 0.4 dBA during the day and from 37.5 ± 0.4 dBA to 71.2 ± 0.1 dBA at night. The levels were 50.9 ± 5.6 dBA in offices, 58.0 ± 5.8 dBA in storage areas, and 63.9 ± 9.2 dBA in drug preparation areas. Considering noise distribution by percentile, the L10 ranged from 43.7 to 71.7 dBA, the L50 from 37.8 to 71.3 dBA, and the L90 from 37.2 to 71.1 dBA. CONCLUSION: Average noise levels varied widely within the pharmacy department of the studied hospital, and a substantial proportion of it could be due to the building's ventilation system.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。