Neglected Aspects of SARS-CoV-2 Aerosol Transmission in Bathrooms of Multistory and High-Rise Buildings - Beijing Municipality, China, October 2022

多层及高层建筑卫生间中SARS-CoV-2气溶胶传播的被忽视方面——北京市,中国,2022年10月

阅读:1

Abstract

WHAT IS ALREADY KNOWN ABOUT THIS TOPIC? There is a toilet flush-soil stack-floor drain pathway of aerosol transmission in multistory and high-rise buildings, but the influencing factors are not completely clear. WHAT IS ADDED BY THIS REPORT? The poor airtightness of the connecting parts of the floor drain, as well as pressure fluctuations in the sewage pipe during toilet flushing caused by blockage of the soil stack vent, may lead to the cross-floor transmission of viral aerosols through the soil stack and floor drains. WHAT ARE THE IMPLICATIONS FOR PUBLIC HEALTH PRACTICE? In multistory and high-rise buildings, the bathroom floor drains should be kept sealed, and floor drain connecting parts should be airtight. Furthermore, the soil stack vent should not be blocked. In this way, the cross-floor transmission of viral aerosols can be effectively reduced.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。