Active Clearance of Chest Tubes Reduces Re-Exploration for Bleeding After Ventricular Assist Device Implantation

主动清除胸管积液可减少心室辅助装置植入术后因出血而需再次手术探查的情况

阅读:1

Abstract

Chest tubes are utilized to evacuate shed blood after left ventricular assist device (LVAD) implantation, however, they can become clogged, leading to retained blood. We implemented a protocol for active tube clearance (ATC) of chest tubes to determine if this might reduce interventions for retained blood. A total of 252 patients underwent LVAD implantation. Seventy-seven patients had conventional chest tube drainage (group 1), whereas 175 patients had ATC (group 2). A univariate and multivariate analysis adjusting for the use of conventional sternotomy (CS) and minimally invasive left thoracotomy (MILT) was performed. Univariate analysis revealed a 65% reduction in re-exploration (43-15%, p < 0.001), and an 82% reduction in delayed sternal closure (DSC; 34-6%, p <0.001). In a sub-analysis of CS only, there continued to be statistically significant 53% reduction in re-exploration (45% vs. 21%, p = 0.0011), and a 77% reduction in DSC (35% vs. 8%, p < 0.001) in group 2. Using a logistic regression model adjusting for CS versus MILT, there was a significant reduction in re-exploration (odds ratio [OR] = 0.44 [confidence interval {CI} = 0.23-0.85], p = 0.014) and DSC (OR = 0.20 [CI = 0.08-0.46], p <0.001) in group 2. Actively maintaining chest tube patency after LVAD implantation significantly reduces re-exploration and DSC.