Evaluation of intraoperative neuromonitoring (IONM) data with the Mainz IONM Quality Assurance and Analysis tool

使用美因茨术中神经监测质量保证和分析工具评估术中神经监测 (IONM) 数据

阅读:1

Abstract

BACKGROUND: Intraoperative neuromonitoring is widely used in thyroid and parathyroid surgery to prevent unilateral and especially bilateral recurrent nerve paresis. Reference values for amplitude and latency for the recurrent laryngeal nerve and vagus nerve have been published. However, data quality measures that exclude errors of the underlying intraoperative neuromonitoring (IONM) data (immanent software errors, false data labelling) before statistical analysis have not yet been implemented. METHODS: The authors developed an easy-to-use application (the Mainz IONM Quality Assurance and Analysis tool) using the programming language R. This tool allows visualization, automated and manual correction, and statistical analysis of complete raw data sets (electromyogram signals of all stimulations) from intermittent and continuous neuromonitoring in thyroid and parathyroid surgery. The Mainz IONM Quality Assurance and Analysis tool was used to evaluate IONM data generated and exported from 'C2' and 'C2 Xplore' neuromonitoring devices (inomed Medizintechnik GmbH) after surgery. For the first time, reference values for latency and amplitude were calculated based on 'cleaned' IONM data. RESULTS: Intraoperative neuromonitoring data files of 1935 patients consecutively operated on from June 2014 to May 2020 were included. Of 1921 readable files, 34 were excluded for missing data labelling. Automated plausibility checks revealed: less than 3 per cent device errors for electromyogram signal detection; 1138 files (approximately 60 per cent) contained potential labelling errors or inconsistencies necessitating manual review; and 915 files (48.5 per cent) were indeed erroneous. Mean(s.d.) reference onset latencies for the left vagus nerve, right vagus nerve, recurrent laryngeal nerve, and external branch of the superior laryngeal nerve were 6.8(1.1), 4.2(0.8), 2.5(1.1), and 2.1(0.5) ms, respectively. CONCLUSION: Due to high error frequencies, IONM data should undergo in-depth review and multi-step cleaning processes before analysis to standardize scientific reporting. Device software calculates latencies differently; therefore reference values are device-specific (latency) and/or set-up-specific (amplitude). Novel C2-specific reference values for latency and amplitude deviate considerably from published values.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。