Intraoperative robotic-assisted low anterior rectal resection performance assessment using procedure-specific binary metrics and a global rating scale

采用手术特异性二元指标和总体评分量表对术中机器人辅助低位直肠前切除术的性能进行评估

阅读:1

Abstract

BACKGROUND: This study aimed to evaluate the use of binary metric-based (proficiency-based progression; PBP) performance assessments and global evaluative assessment of robotic skills (GEARS) of a robotic-assisted low anterior rectal resection (RA-LAR) procedure. METHOD: A prospective study of video analysis of RA-LAR procedures was carried out using the PBP metrics with binary parameters previously developed, and GEARS. Recordings were collected from five novice surgeons (≤30 RA-LAR previously performed) and seven experienced surgeons (>30 RA-LAR previously performed). Two consultant colorectal surgeons were trained to be assessors in the use of PBP binary parameters to evaluate the procedure phases, surgical steps, errors, and critical errors in male and female patients and GEARS scores. Novice and experienced surgeons were categorized and assessed using PBP metrics and GEARS; mean scores obtained were compared for statistical purpose. Also, the inter-rater reliability (IRR) of these assessment tools was evaluated. RESULTS: Twenty unedited recordings of RA-LAR procedures were blindly assessed. Overall, using PBP metric-based assessment, a subgroup of experienced surgeons made more errors (20 versus 16, P = 0.158) and critical errors (9.2 versus 7.8, P = 0.417) than the novice group, although not significantly. However, during the critical phase of RA-LAR, experienced surgeons made significantly fewer errors than the novice group (95% CI of the difference, Lower = 0.104 - Upper = 5.155, df = 11.9, t = 2.23, p = 0.042), and a similar pattern was observed for critical errors. The PBP metric and GEARS assessment tools distinguished between the objectively assessed performance of experienced and novice colorectal surgeons performing RA-LAR (total error scores with PBP metrics, P = 0.019-0.008; GEARS scores, P = 0.029-0.025). GEARS demonstrated poor IRR (mean IRR 0.49) and weaker discrimination between groups (15-41 per cent difference). PBP binary metrics demonstrated good IRR (mean 0.94) and robust discrimination particularly for total error scores (58-64 per cent). CONCLUSIONS: PBP binary metrics seem to be useful for metric-based training for surgeons learning RA-LAR procedures.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。