Safety and Tolerability of Manual Push Administration of Subcutaneous IgPro20 at High Infusion Rates in Patients with Primary Immunodeficiency: Findings from the Manual Push Administration Cohort of the HILO Study

在原发性免疫缺陷患者中,以高输注速率手动推注皮下注射IgPro20的安全性和耐受性:HILO研究手动推注给药队列的研究结果

阅读:1

Abstract

PURPOSE: To evaluate the safety and tolerability of IgPro20 manual push (also known as rapid push) infusions at flow rates of 0.5-2.0 mL/min. METHODS: Patients with primary immunodeficiency (PID) with previous experience administering IgPro20 (Hizentra(®), CSL Behring, King of Prussia, PA, USA) were enrolled in the Hizentra(®) Label Optimization (HILO) study (NCT03033745) and assigned to Pump-assisted Volume Cohort, Pump-assisted Flow Rate Cohort, or Manual Push Flow Rate Cohort; this report describes the latter. Patients administered IgPro20 via manual push at 0.5, 1.0, and 2.0 mL/min/site for 4 weeks each. Responder rates (percentage of patients who completed a predefined minimum number of infusions), safety outcomes, and serum immunoglobulin G (IgG) trough levels were evaluated. RESULTS: Sixteen patients were treated; 2 patients (12.5%) discontinued at the 1.0-mL/min level (unrelated to treatment). Responder rates were 100%, 100%, and 87.5% at 0.5-, 1.0-, and 2.0-mL/min flow rates, respectively. Mean weekly infusion duration decreased from 103-108 to 23-28 min at the 0.5- and 2.0-mL/min flow rates, respectively. Rates of treatment-related treatment-emergent adverse events (TEAEs) per infusion were 0.023, 0.082, and 0.025 for the 0.5-, 1.0-, and 2.0-mL/min flow rates, respectively. Most TEAEs were mild local reactions and tolerability (infusions without severe local reactions/total infusions) was 100% across flow rate levels. Serum IgG levels (mean [SD]) were similar at study start (9.36 [2.53] g/L) and end (9.58 [2.12] g/L). CONCLUSIONS: Subcutaneous IgPro20 manual push infusions at flow rates up to 2.0 mL/min were well tolerated and reduced infusion time in treatment-experienced patients with PID. TRIAL REGISTRATION: NCT03033745.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。