The Successful Measurement of Clitoral Pulse Amplitude Using a New Clitoral Photoplethysmograph: A Pilot Study

利用新型阴蒂光电容积脉搏波描记仪成功测量阴蒂脉搏振幅:一项初步研究

阅读:1

Abstract

BACKGROUND: Although the clitoris is more sensitive to stimulation and its innervation more conducive to sensory feedback than the vagina, the field of sexual psychophysiology, which uses psychophysiological methods including genital response measures to study sexual arousal, relies heavily on the measurement of vaginal, rather than clitoral, pulse amplitude. AIM: To develop and test a new clitoral photoplethysmograph for the measurement of clitoral pulse amplitude (CPA). METHODS: 2 versions of the new device, which differed in the orientation of the sensor and light source (parallel vs angled), were tested in 15 premenopausal, sexually functional women. Vaginal pulse amplitude (VPA) was assessed simultaneously. The women viewed a 3-minute erotic and an anxiety-inducing film segment with each clitoral sensor, interspersed with neutral video excerpts. In addition, they were asked to indicate their subjective level of sexual arousal during and after erotic video presentations. OUTCOMES: The main outcome measures are CPA, VPA, and subjective sexual arousal. RESULTS: The clitoral photoplethysmograph successfully detected CPA. The quality of the signals was best for the angled sensor. Main effects of the film and the interaction between the film and epoch were stronger for the clitoral than for the vaginal device. In addition, CPA followed more closely changes in intensity of sexual films than VPA. Within- and between-subject correlations between genital response and subjective sexual arousal were higher for the clitoral than for the vaginal device. CLINICAL TRANSLATION: Comparison of CPA with other genital blood flow measures in clinical samples is indicated and may contribute to improved physiological assessments of sexual response in women. STRENGTHS AND LIMITATIONS: Our sample was small and consisted of healthy volunteers. Future research could examine test-retest reliability, by including multiple recording sessions, and further explore the specificity of CPA by comparing sexual and non-sexual stimuli with positive valence. CONCLUSION: This study presents the first instrument to successfully measure CPA. Mechelmans DJ, Sachtler WL, von Wiegand TE, et al. The Successful Measurement of Clitoral Pulse Amplitude Using a New Clitoral Photoplethysmograph: A Pilot Study. J Sex Med 2020;17:1118-1125.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。