High-resolution peripheral quantitative computed tomography reliability and accuracy of bone density and morphology properties in children

儿童高分辨率外周定量计算机断层扫描骨密度和形态特征的可靠性和准确性

阅读:3

Abstract

Volumetric bone density, microarchitecture, and strength measures using HR-pQCT are valuable measures of bone health in pediatrics. Our cross-sectional study evaluated bone measure reproducibility in pediatric participants using repeat HR-pQCT (XtremeCT II, Scanco Medical) scans of non-dominant distal tibia and radius of 30 healthy children and adolescents (7-17 yr, 47% female) by 2 technicians. Additionally, we examined HR-pQCT and micro-CT of 26 cadaveric distal tibia specimens to evaluate agreement between the modalities. All HR-pQCT scans were analyzed using manufacturer-provided software (Image Processing Language, Scanco Medical) and a fully automated, previously validated, in-house algorithm, offering measures of bone microstructure (eg, trabecular plate-rod distribution, transverse trabeculae, trabecular bone strength) currently unavailable in the manufacturer-provided software. Root-mean-squared percent coefficient of variation (RMS-%CV) assessed precision and least significant change. Intraclass correlation coefficients (ICCs) using absolute-agreement, 2-way random-effects models assessed reliability. Pearson's correlation coefficients and ICC assessed linear relationships and agreements between HR-pQCT and micro-CT, respectively. In children and adolescents, RMS-%CV of HR-pQCT-derived trabecular bone measures at distal tibia and radius ranged from 0.8-4.4 to 0.8-6.0, respectively. Most cortical bone results were in a similar range. Both computational algorithms showed ICC > 0.90. RMS-%CV and least significant change values were lower for tibia than radius. ICCs were lower for cortical than trabecular outcomes. Most cadaveric results showed ICC > 0.83, other than trabecular bone thickness and modulus (ICC = 0.7). Pearson's r (>0.86) suggested strong correlations for almost all parameters. HR-pQCT and micro-CT results using in-house algorithm did not differ significantly, while manufacturer-provided algorithm results showed lower yet still moderate reliability (ICC > 0.55). Reliability of the second-generation HR-pQCT in pediatric participants is excellent-better in tibia vs radius. Our results support the high reproducibility of XtremeCT II scans and thus the use of this clinical imaging modality in studies of pediatric bone health.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。