Manual Replacement of Double J Stent Without Fluoroscopy (Double j stent replacement)

无需透视引导的手动双J支架置换术(双J支架置换术)

阅读:1

Abstract

It is not always possible to replace a ureteric stent with a new one due to the fact that tumoral effect increases in ureter with time. We present our experience of manual replacement of double J stent without fluoroscopy. The data from 23 female patients who underwent double J stent replacement with a total of 110 times was retrospectively analyzed. The steps of technique are as follows: take out distal end of the double J stent through urethra to external urethral meatus cystoscopically, insert a 0.035-inch guide wire through double J stent to the renal pelvis or intra pelvicaliceal system, take out old double J stent over guide wire, slide new stent over guide wire and at external meatus level take out guide wire while gently sliding distal end of double J stent over guide wire into urethra. The mean age was 58.39 ± 9.21 years. Cervical, endometrial, and ovarian cancer were diagnosed in 16, 4, and 3 patients respectively. The mean follow-up and indwelling period were 13.8 ± 5.2, 3.8 ± 0.6 months, respectively. Increased pelvicaliceal dilatation, serum creatinine level, or renal parenchymal loss was not observed. Replacement of double J stents with this technique is easy and can be used successfully in distal ureteral obstructions.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。