A review on the safety of one-stage circumferential ring constriction release

单阶段环形缩窄释放术安全性综述

阅读:1

Abstract

The study was undertaken to investigate the use of one-stage circumferential ring-constriction release with Z-plasties regarding the safety, aesthetic appearance, and limb function. A thorough review was conducted on all English publications in PubMed during the period of 2001 through 2011. Titles and abstracts were identified using online search engine from National Library of Medicine's PubMed database under the keywords "limb constriction ring," "limb constriction band," "amniotic band," "annular constriction," and "circumferential constriction." We used Boolean operator and field of title. Evaluation was done to search indications, timing of the first surgical intervention, time interval between surgeries, patients' gender, anatomic location of the ring, wound healing problems, and scar quality. Fourteen publications met the criteria. There were 17 patients with 25 ring constrictions in total. Sixteen ring constrictions (64%) were circumferential; nine (36%) were semi-circumferential. Mean age of 14 patients treated with one-stage release was 4.8 years. Six articles mentioned about normal development of postoperative limb function. Mean age of three patients treated with staged release was 10.5 months. Two articles mentioned regained distal muscle function postoperatively. It is confirmed that surgeons may continue the practice to release circumferential CRS in one stage.

特别声明