Incontinence pessaries: size, POPQ measures, and successful fitting

尿失禁托:尺寸、盆腔器官脱垂定量分期(POPQ)测量及成功佩戴

阅读:1

Abstract

INTRODUCTION AND HYPOTHESIS: The aim of the study was to determine whether successful incontinence pessary fitting or pessary size can be predicted by specific POPQ measurements in women without advanced pelvic organ prolapse. METHODS: In a multicenter study, women with stress urinary incontinence (SUI) and POPQ stage < or = 2 were randomized to three treatment arms: (1) incontinence pessary, (2) behavioral therapy, or (3) both. This study evaluates incontinence pessary size, POPQ measures, and successful fitting in the 266 women assigned to treatment arms 1 and 3. RESULTS: Two hundred thirty-five women (92%) were successfully fitted with an incontinence ring (n = 122) or dish (n = 113). Hysterectomy, genital hiatus (GH), and GH/total vaginal length (TVL) ratios did not predict unsuccessful fitting (p > 0.05). However, mean TVL was greater in women successfully fitted (9.6 vs. 8.8 cm, p < 0.01). Final pessary diameter was not predicted by TVL, point D, or point C (p > 0.05). CONCLUSIONS: The vast majority of women with SUI can be successfully fitted with an incontinence pessary, but specific POPQ measures were not helpful in determining incontinence pessary size.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。