Prediction of functional coronary stenosis by computed tomography-derived fractional flow reserve in surgical revascularization

利用计算机断层扫描衍生的血流储备分数预测外科血运重建中的功能性冠状动脉狭窄

阅读:2

Abstract

OBJECTIVES: The aims of this study were (1) to compare computed tomography-derived fractional flow reserve (CT-FFR) values with graft patency and (2) to establish the cut-off value of CT-FFR for predicting competitive graft flow after coronary artery bypass grafting (CABG). METHODS: Of the 77 patients who underwent isolated CABG with an in situ internal thoracic artery (ITA)-based composite graft and who were also evaluated by preoperative cardiac CT, CT-FFR values were obtained in 74 patients. Early postoperative angiograms were performed in all 74 patients. Angiograms were performed to evaluate the grafts as well as the native coronary arteries to find any competitive flow present. Postoperative angiographic findings of graft flow were categorized as perfectly patent, bidirectionally competitive, unidirectionally competitive, and occluded. Receiver operating characteristic curve analysis of preoperative CT-FFR values for predicting postoperative angiographic competition was performed, and cutoff values of CT-FFR and area under the curve were identified. RESULTS: In total, 234 anastomoses were performed in 74 patients (median 3 [interquartile range, 2, 4] anastomoses per patient). Postoperative (median 1 [interquartile range, 1, 2] day) angiograms showed that 196 (83.8%) anastomoses were perfectly patent, 25 (10.7%) anastomoses were bidirectionally competitive, 12 (5.1%) anastomoses were unidirectionally competitive, and 1 (0.4%) anastomosis was occluded. Median CT-FFR values of the coronary arteries with perfectly patent, bidirectionally competitive, and unidirectionally competitive grafts were 0.658 (interquartile range, 0.500, 0.725), 0.809 (interquartile range, 0.789, 0.855), and 0.849 (interquartile range, 0.833, 0.865), respectively. The cutoff value of CT-FFR predicting competitive graft flow was 0.774 (sensitivity, 97.4%; specificity, 98.5% [area under the curve 0.977; P < .001]). CONCLUSIONS: The diagnostic accuracy of CT-FFR for predicting competitive graft flow after CABG was high, and CT-FFR could be used as a guide for predicting functional coronary artery stenosis in surgical revascularization.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。