Transcatheter closure of patent ductus arteriosus in infants weighing less than 6 kilograms - a two-center experience. Technical considerations

经导管封堵体重不足6公斤婴儿的动脉导管未闭——两中心经验。技术考量

阅读:1

Abstract

BACKGROUND: Transcatheter closure has become the method of choice for treating patent ductus arteriosus (PDA) in a majority of patients. The only approved device for treating infants weighing less than 6 kilograms is the Amplatzer Piccolo Occluder (APO). The aim of this study is to summarize the experience of two centers in performing transcatheter PDA closure in infants weighing less than 6 kilograms. METHODS: Retrospective, descriptive, and nonrandomized analysis included all 45 infants weighing less than 6 kg who underwent transcatheter PDA closure between 2013 and 2023 at two tertiary centers, following the introduction of APO. Medical records, procedural outcomes, and one-month follow-up were analyzed. Applied devices were: APO in 37 (of whom 3 were off-label due to PDA size), Amplatzer Duct Occluder I (ADO) in 3, and Amplatzer Vascular Plug II (AVP) in 5 cases. RESULTS: The overall success rate was 97.8%. There were 2 major complications (4.4%), including one device protrusion. A residual shunt was noted in one patient 24 hours after the procedure, but none were observed after one month. Off-label devices were implanted in insignificantly larger and longer PDAs. There were no significant differences between the labeled and off-label groups in terms of procedural success, major complications, or residual shunts. CONCLUSIONS: APO is a safe and effective device to treat PDA in infants weighing less than 6 kilograms, however, off-label devices are needed in a considerable number of patients. Proper use of off-label devices yields comparable to APO results.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。