An ultra-wide scanner for large-area high-speed atomic force microscopy with megapixel resolution

一种用于大面积高速原子力显微镜的超宽扫描器,具有百万像素分辨率

阅读:1

Abstract

High-speed atomic force microscopy (HS-AFM) is a powerful tool for visualizing the dynamics of individual biomolecules. However, in single-molecule HS-AFM imaging applications, x,y-scanner ranges are typically restricted to a few hundred nanometers, preventing overview observation of larger molecular assemblies, such as 2-dimensional protein crystal growth or fibrillar aggregation. Previous advances in scanner design using mechanical amplification of the piezo-driven x,y-positioning system have extended the size of HS-AFM image frames to several tens of micrometer, but these large scanners may suffer from mechanical instabilities at high scan speeds and only record images with limited pixel numbers and comparatively low lateral resolutions (> 20-100 nm/pixel), complicating single-molecule analysis. Thus, AFM systems able to image large sample areas at high speeds and with nanometer resolution have still been missing. Here, we describe a HS-AFM sample-scanner system able to record large topographic images (≤ 36 × 36 µm(2)) containing up to 16 megapixels, providing molecular resolution throughout the image frame. Despite its large size, the flexure-based scanner features a high resonance frequency (> 2 kHz) and delivers stable operation even at high scans speeds of up to 7.2 mm/s, minimizing the time required for recording megapixel scans. We furthermore demonstrate that operating this high-speed scanner in time-lapse mode can simultaneously identify areas of spontaneous 2-dimensional Annexin A5 crystal growth, resolve the angular orientation of large crystalline domains, and even detect rare crystal lattice defects, all without changing scan frame size or resolution. Dynamic processes first identified from overview scans can then be further imaged at increased frame rates in reduced scan areas after switching to conventional HS-AFM scanning. The added ability to collect large-area, high-resolution images of complex samples within biological-relevant time frames extends the capabilities of HS-AFM from single-molecule imaging to the study of large dynamic molecular arrays. Moreover, large-area HS-AFM scanning can generate detailed structural data sets from a single scan, aiding the quantitative analysis of structurally heterogenous samples, including cellular surfaces.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。