Predictive capability of near-infrared fluorescence angiography in submental perforator flap survival

近红外荧光血管造影对颏下穿支皮瓣存活的预测能力

阅读:4
作者:Aya Matsui, Bernard T Lee, Joshua H Winer, Rita G Laurence, John V Frangioni

Background

Perforator flaps have become increasingly popular in reconstructive surgery, as patients experience less donor-site morbidity than with conventional musculocutaneous flaps. Previously, the authors' laboratory described the intraoperative use of near-infrared fluorescence angiography for patient-specific perforator flap design. This study evaluates the predictive capability of near-infrared fluorescence angiography for flap survival in submental flap reconstruction.

Conclusions

The use of near-infrared angiography immediately after flap creation can predict areas of perfusion at 72 hours. This predictive capability may permit intraoperative revision of compromised flaps that have a high likelihood of failure.

Methods

Near-infrared angiography was performed using indocyanine green at 0, 0.5, 24, 48, and 72 hours after surgery for flap creation in 12 pigs. A single perforator artery was preserved during flap creation based on location (central or noncentral) and dominance (dominant or nondominant). Venous drainage, arterial perfusion, and perfused area as a percentage of total flap area were analyzed. Clinical assessments of perfusion were compared with those made using near-infrared imaging and histology.

Results

Use of near-infrared fluorescence angiography immediately after flap creation accurately predicted areas of perfusion at 72 hours (p=0.0013), compared with the initial clinical assessment (p=0.3085). Identification of necrosis by histology at 72 hours correlated with near-infrared findings of insufficient arterial perfusion immediately after flap creation. No statistically significant differences in perfusion metrics were detected based on location or dominance of the preserved perforator; however, flaps containing central perforators had a higher percentage perfused area than those with noncentral perforators. Conclusions: The use of near-infrared angiography immediately after flap creation can predict areas of perfusion at 72 hours. This predictive capability may permit intraoperative revision of compromised flaps that have a high likelihood of failure.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。