Evaluation of Diagnostic Accuracy Following the Coadministration of Delta-Aminolevulinic Acid and Second Window Indocyanine Green in Rodent and Human Glioblastomas

评估δ-氨基乙酰丙酸和第二窗口吲哚菁绿联合给药后对啮齿动物和人类胶质母细胞瘤的诊断准确性

阅读:1

Abstract

PURPOSE: Fluorescence-guided-surgery offers intraoperative visualization of neoplastic tissue. Delta-aminolevulinic acid (5-ALA), which targets enzymatic abnormality in neoplastic cells, is the only approved agent for fluorescence-guided neurosurgery. More recently, we described Second Window Indocyanine Green (SWIG) which targets neoplastic tissue through enhanced vascular permeability. We hypothesized that SWIG would demonstrate similar clinical utility in identification of high-grade gliomas compared with 5-ALA. PROCEDURES: Female C57/BL6 and nude/athymic mice underwent intracranial implantation of 300,000 GL261 and U87 cells, respectively. Tumor-bearing mice were euthanized after administration of 5-ALA (200 mg/kg intraperitoneal) and SWIG (5 mg/kg intravenous). Brain sections were imaged for protoporphyrin-IX and ICG fluorescence. Fluorescence and H&E images were registered using semi-automatic scripts for analysis. Human subjects with HGG were administered SWIG (2.5 mg/kg intravenous) and 5-ALA (20 mg/kg oral). Intraoperatively, tumors were imaged for ICG and protoporphyrin-IX fluorescence. RESULTS: In non-necrotic tumors, 5-ALA and SWIG demonstrated 90.2 % and 89.2 % tumor accuracy (p value = 0.52) in U87 tumors and 88.1 % and 87.7 % accuracy (p value = 0.83) in GL261 tumors. The most distinct difference between 5-ALA and SWIG distribution was seen in areas of tumor-associated necrosis, which often showed weak/no protoporphyrin-IX fluorescence, but strong SWIG fluorescence. In twenty biopsy specimens from four subjects with HGG, SWIG demonstrated 100 % accuracy, while 5-ALA demonstrated 75-85 % accuracy; there was 90 % concordance between SWIG and 5-ALA fluorescence. CONCLUSION: Our results provide the first direct comparison of the diagnostic utility of SWIG vs 5-ALA in both rodent and human HGG. Given the broader clinical utility of SWIG compared with 5-ALA, our data supports the use of SWIG in tumor surgery to improve the extent of safe resections. CLINICAL TRIAL: NCT02710240 (US National Library of Medicine Registry; https://www.clinicaltrials.gov/ct2/show/NCT02710240?id=NCT02710240&draw=2&rank=1 ).

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。