HPTLC Method for the Simultaneous Estimation of Valsartan and Hydrochlorothiazide in Tablet Dosage Form

高效薄层色谱法同时测定片剂中缬沙坦和氢氯噻嗪的含量

阅读:1

Abstract

A simple, precise, accurate and rapid high performance thin layer chromatographic method has been developed and validated for the simultaneous estimation of valsartan and hydrochlorothiazide in combined dosage forms. The stationary phase used was precoated silica gel 60F(254). The mobile phase used was a mixture of chloroform: methanol: toluene: glacial acetic acid (6:2:1:0.1 v/v/v/v). The detection of spots were carried out at 260 nm. The method was validated in terms of linearity, accuracy, precision and specificity. The calibration curve was found to be linear between 300 to 800 ng/spot for valsartan and 100 to 600 ng/spot for hydrochlorothiazide. The limit of detection and the limit of quantification for the valsartan were found to be 100 and 300 ng/spot respectively and for hydrochlorothiazide 30 and 100 ng/spot respectively. The proposed method can be successfully used to determine the drug content of marketed formulation.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。