Stress Perfusion Cardiac Magnetic Resonance Imaging With a 3.0-Tesla Scanner for Myocardial Viability in a Patient With a Conditional Pacemaker

使用 3.0 特斯拉扫描仪对植入条件性起搏器的患者进行负荷灌注心脏磁共振成像以评估心肌活力

阅读:1

Abstract

Cardiac magnetic resonance (CMR) imaging provides images with high spatial and temporal resolution, with high diagnostic and prognostic performance. An abundance of data indicate the safety and efficacy of noncardiac magnetic resonance imaging at both 1.5 Tesla (T) and 3T in patients with cardiac implantable electronic devices (CIEDs). Safety and efficacy have also been evaluated for stress perfusion (SP)-CMR for pateints with CIEDs, using 1.5T scanners, but no previous reports have been made of SP-CMR using 3T scanners. Herein, we report a case of a patient with a CIED who successfully and safely underwent SP-CMR imaging using a 3T scanner.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。