Convolutional neural networks combined with conventional filtering to semantically segment plant roots in rapidly scanned X-ray computed tomography volumes with high noise levels

卷积神经网络结合传统滤波技术,对高噪声水平的快速扫描X射线计算机断层扫描图像中的植物根系进行语义分割。

阅读:1

Abstract

BACKGROUND: X-ray computed tomography (CT) is a powerful tool for measuring plant root growth in soil. However, a rapid scan with larger pots, which is required for throughput-prioritized crop breeding, results in high noise levels, low resolution, and blurred root segments in the CT volumes. Moreover, while plant root segmentation is essential for root quantification, detailed conditional studies on segmenting noisy root segments are scarce. The present study aimed to investigate the effects of scanning time and deep learning-based restoration of image quality on semantic segmentation of blurry rice (Oryza sativa) root segments in CT volumes. RESULTS: VoxResNet, a convolutional neural network-based voxel-wise residual network, was used as the segmentation model. The training efficiency of the model was compared using CT volumes obtained at scan times of 33, 66, 150, 300, and 600 s. The learning efficiencies of the samples were similar, except for scan times of 33 and 66 s. In addition, The noise levels of predicted volumes differd among scanning conditions, indicating that the noise level of a scan time ≥ 150 s does not affect the model training efficiency. Conventional filtering methods, such as median filtering and edge detection, increased the training efficiency by approximately 10% under any conditions. However, the training efficiency of 33 and 66 s-scanned samples remained relatively low. We concluded that scan time must be at least 150 s to not affect segmentation. Finally, we constructed a semantic segmentation model for 150 s-scanned CT volumes, for which the Dice loss reached 0.093. This model could not predict the lateral roots, which were not included in the training data. This limitation will be addressed by preparing appropriate training data. CONCLUSIONS: A semantic segmentation model can be constructed even with rapidly scanned CT volumes with high noise levels. Given that scanning times ≥ 150 s did not affect the segmentation results, this technique holds promise for rapid and low-dose scanning. This study offers insights into images other than CT volumes with high noise levels that are challenging to determine when annotating.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。