Assessment of the Safety Risk of Dermatoscope Magnets in Patients With Cardiovascular Implanted Electronic Devices

评估皮肤镜磁铁对植入心血管电子设备患者安全风险

阅读:1

Abstract

IMPORTANCE: Cardiovascular implanted electronic devices (CIEDs) are susceptible to electromagnetic interference. Dermatologists regularly use devices containing magnets, including dermatoscopes and their attachments, which could pose a hazard to patients with CIEDs. OBJECTIVE: To investigate the safety risk of magnets in dermatoscopes to patients with CIEDs. DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional observational study was conducted between January 1, 2018, and March 31, 2018, in a controlled laboratory setting. Two experiments were performed. In the first experiment (performed in the Dermatology Service at Memorial Sloan Kettering Cancer Center, New York), dermatoscopes that contain magnets were obtained from 3 manufacturers. Using a magnometer, the magnetic field strength of the dermatoscopes was measured over the magnet; at the faceplate; and at a distance of 0.5 cm, 1 cm and 15 cm away from the faceplate. In the second experiment (performed in the University Heart Center Zurich, Zurich, Switzerland), ex vivo measurements were conducted to determine how the dermatoscopes affected old-generation and new generation CIEDs (pacemakers and implantable defibrillators). MAIN OUTCOMES AND MEASURES: Magnetic field strength as measured directly over the dermatoscope magnet; at the faceplate; and at distances of 0.5 cm, 1 cm, and 15 cm from the faceplate. Pacemaker and defibrillator operation when exposed to dermatoscopes. RESULTS: After conducting 24 measurements, the magnetic field (measured in gauss [G]) strength varied between 24.26 G and 163.04 G over the dermatoscope magnet, between 2.22 G and 9.98 G at the dermatoscope faceplate, between 0.82 G and 2.4 G at a distance of 0.5 cm, and between 0.5 G and 1.04 G at a distance of 1 cm; it was 0 for all devices at a 15 cm distance. The field strength at the faceplate was found to be generally below the CIED industry standard safety threshold. None of the dermatoscopes in the ex vivo experiment exerted any demonstrable disruptions or changes to the CIEDs. CONCLUSIONS AND RELEVANCE: In real life, dermatoscope magnets likely present no measurable safety risk to patients with CIEDs. Using the polarized noncontact mode permits dermoscopy to be performed at least 0.5 cm from the skin surface, where the magnetic field strength was well below the 5-G safety threshold.

特别声明

1、本页面内容包含部分的内容是基于公开信息的合理引用;引用内容仅为补充信息,不代表本站立场。

2、若认为本页面引用内容涉及侵权,请及时与本站联系,我们将第一时间处理。

3、其他媒体/个人如需使用本页面原创内容,需注明“来源:[生知库]”并获得授权;使用引用内容的,需自行联系原作者获得许可。

4、投稿及合作请联系:info@biocloudy.com。